2191JDV28 cover12/10/99 djtINSTALLER / CONSUMER SAFETY INFORMATION30004177 2/08 Rev. 1PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIAN
1010Jefferson Direct Vent/Natural Vent Gas Heater 30004177Vent Termination ClearancesYour stove is approved to be vented either through the side wall,
11Jefferson Direct Vent /Natural Vent Gas Heater30004177VVVVVVVXXXDEBBBCBMBAJKFLVENT TERMINATION AIR SUPPLY INLETAREA WHERE TERMINAL IS NOT PERMITTED
1212Jefferson Direct Vent/Natural Vent Gas Heater 30004177Fig. 10 Termination clearances.Outside CornerInside CornerTermination ClearancesTermination
13Jefferson Direct Vent /Natural Vent Gas Heater30004177Venting Requirements and Options - Direct Vent ONLYApproved Vent System ComponentsThe Jefferso
1414Jefferson Direct Vent/Natural Vent Gas Heater 30004177Assembly Procedures Failure to position the parts in accor-dance with these diagrams or fail
15Jefferson Direct Vent /Natural Vent Gas Heater30004177Venting System Assembly - Direct VentGeneral InformationThe Jefferson is approved for installa
1616Jefferson Direct Vent/Natural Vent Gas Heater 300041774. Attach the Inner Vent Assembly to the stove.• Run a bead of sealant around the bottom e
17Jefferson Direct Vent /Natural Vent Gas Heater300041772. Measure the wall thickness and cut the wall sleeve sections to proper length (MAXIMUM 12”)
1818Jefferson Direct Vent/Natural Vent Gas Heater 300041776. Install the elbow using 3 sheet metal screws at each joint. 7. Measure, and cut if need
19Jefferson Direct Vent /Natural Vent Gas Heater30004177ST218install snorkel12/6/99 djtWall Screws and AnchorsSnorkel Termination CapWaterproof Se
22Jefferson Direct Vent/Natural Vent Gas Heater 30004177PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.Thank you and
2020Jefferson Direct Vent/Natural Vent Gas Heater 30004177ST221vent thru roof12/99Storm CollarSealantUpper edge of flange goes under upper shinglesFl
21Jefferson Direct Vent /Natural Vent Gas Heater30004177Install the Log Set1. Remove the logs from their packaging and inspect each piece for damage.
2222Jefferson Direct Vent/Natural Vent Gas Heater 30004177Connect the Gas Supply LineCheck the Rating Plate attached by a steel cable to the firebox, t
23Jefferson Direct Vent /Natural Vent Gas Heater300041773. Pull the top edge of the glass and frame assembly away from the firebox and lift it off its
2424Jefferson Direct Vent/Natural Vent Gas Heater 30004177Fig. 41 Remove and replace injector orifices.ST353ainjector orificereplace3/21/00 djt9
25Jefferson Direct Vent /Natural Vent Gas Heater30004177OperationYour First FireRead these instructions carefully and familiarize yourself with the bu
2626Jefferson Direct Vent/Natural Vent Gas Heater 300041773. Open control access panel.4. Push in gas control knob slightly and turn clock-wise t
27Jefferson Direct Vent /Natural Vent Gas Heater30004177Troubleshooting / Honeywell #8420 Gas Control SystemNOTE: Before troubleshooting the gas contr
2828Jefferson Direct Vent/Natural Vent Gas Heater 30004177Conversion PrecautionsBefore proceeding, turn control knob on valve to OFF and turn gas supp
29Jefferson Direct Vent /Natural Vent Gas Heater30004177• Remove pilot orifice with needlenose pliers. (Fig. 57) NOTE: Use a wrench to hold pilot tube
3Jefferson Direct Vent /Natural Vent Gas Heater30004177The Jefferson Direct Vent/Natural Vent Room Heater, Model No. JDVBRN, is a vented gas applianc
3030Jefferson Direct Vent/Natural Vent Gas Heater 30004177MaintenanceYour Jefferson Gas Heater will provide years of service with minimal upkeep. The
31Jefferson Direct Vent /Natural Vent Gas Heater30004177Gasket ReplacementThe Jefferson Gas Heater uses a ‘tadpole’ type gasket to seal between the gl
3232Jefferson Direct Vent/Natural Vent Gas Heater 30004177NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP-PLIED WITH THE APPLIANCE, MUST BE RE-PLACED, IT MU
33Jefferson Direct Vent /Natural Vent Gas Heater300041771a1b1c1d1eCEMENT4521091137171829301283132151633342122 23242527263619353671420a,b
3434Jefferson Direct Vent/Natural Vent Gas Heater 30004177 Ref. Descripción JDVB 7. Right End 30000681 8. Front 30000683 9. Glass 200021
35Jefferson Direct Vent /Natural Vent Gas Heater30004177Optional AccessoriesFan KitsFK28 FanThe FK28 fan helps distribute heated air from within the fi
3636Jefferson Direct Vent/Natural Vent Gas Heater 30004177
37Jefferson Direct Vent /Natural Vent Gas Heater30004177
3838Jefferson Direct Vent/Natural Vent Gas Heater 30004177
39Jefferson Direct Vent /Natural Vent Gas Heater30004177This Warranty gives you specific legal rights and you may also have other rights that vary in e
44Jefferson Direct Vent/Natural Vent Gas Heater 30004177Requirements for the Commonwealth of MassachusettsAll gas fitting and installation of this heat
Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) JDVBRN 60.7 JDVBRP 60.72695 Meadowvale Blvd. • Mississauga, Ontario, Canada
5Jefferson Direct Vent /Natural Vent Gas Heater30004177ST205FDV28dimensions12/3/99 djt28"(724 mm)24"(610 mm)3"(76 mm)14"(3
66Jefferson Direct Vent/Natural Vent Gas Heater 30004177Installation RequirementsThe installation must conform with local codes or, in the absence of
7Jefferson Direct Vent /Natural Vent Gas Heater30004177Hearth Requirements The Jefferson Heater must be installed on rigid flooring. When the heater is
88Jefferson Direct Vent/Natural Vent Gas Heater 30004177Gas Specifications Max. Min. Input Input Model Fuel Gas Control BTU/h BTU/
9Jefferson Direct Vent /Natural Vent Gas Heater30004177Vent Termination ClearancesWhen planning the installation, consider the location of the vent te